Hydraulic shock and sway suppressors (snubbers)

Application | Performance | Construction Features | Models available
| Standard Settings and Test Values at Room Temperature
Allowable Loads
| Technical Data

 

Allowable Loads

Cylinder - bore
size
Figure
Figure
with
extension
1 x FN
Load case H*
1,5 x FN
Load case HZ*
1,7 x FN
Load case HS*
(inches)
  A/B** Normal/Upset C** Emergency D** Faulted
1/4, 1/2, 1
200A
201A
7 10 12
1 1/2
200A,200B
201A,201B
13 20 22
2 1/2
200A,200B
201A,201B
45 68 77
3 1/4
200A,200B
201A,201B
78 117 133
4
200A
201A
121 182 206
5
200A
201A
202 303 343
6
200A
201A
303 455 515
8 1/2
202B
203
590 885 1003
10
202B
203
835 1253 1419
12
202B
203
1200 1800 2040
14
202B
203
1730 2595 2941
17
202B
203
2470 3705 4199
20 1/2
202B
203
3610 5415 6137
24 1/2
202B
203
5130 7695 8721
29 1/2
202B
203
7510 11265 12767
35 1/2
202B
203
10815 16223 18385
43
202B
203
16155 24233 27463

  * = KTA Nuclear Safety Standards Commission 3205.3
** = ASME Section III, Sub-section NF